IJMTES – IMPLEMENTATION OF STATCOM BASED CONTROL SCHEME FOR POWER QUALITY IMPROVEMENT IN SOLAR POWER GENERATION

Journal Title : International Journal of Modern Trends in Engineering and Science

Author’s Name : D Vinothini | S Rathinamala

Volume 02 Issue 09  Year 2015

ISSN no: 2348-3121

Page no: 1-3

Abstract The photovoltaic power generation is a distribution resources whose output changes rapidly due to the environmental conditions and due to the nature of the non linear load also power quality issues occurred in it. Power quality issues are harmonics, voltage sag, voltage swell, voltage fluctuations and waveform distortions. To overcome the power quality issues STATCOM Based Voltage Source Inverter is used to reduce the harmonics content of the load current at the point of common coupling. By injecting the current into the grid can achieve pure sinusoidal waveform with the fundamental frequency of 50HZ Therefore the system life time has been increased and these system is implemented in hardware.

Keywords— Power Quality; Photovoltaic source; STATCOM

Reference

[1] Bhatia R.S and Jain.D “Battery energy storage system for power conditioning of renewable energy sources,” in Proc. Int. Conf. Power Electron Drives System, Jan. 2006, vol. 1, pp. 501–506.
[2] Billinton.R and Gao,Y “Energy conversion system models for adequacy assessment of generating systems incorporating wind energy,” IEEE Trans. on Energy Conv., Vol. 23, No. 1, pp. 163–169, 2008, Multistate.
[3] Gutierrez J.J, Ruiz.J, Leturiondo.L, and Lazkano.A, “Flicker measurement system for wind turbine certification,” IEEE Trans. Instrum. Meas., Vol. 58, No. 2, pp. 375–382, Feb. (2009).
[4] Han.C, Huang A.Q, Baran,M, Bhattacharya.M and Litzenberger.W, “STATCOM impact study on the integration of a large wind farm into a weak loop power system,” IEEE Trans. Energy Conv., Vol. 23, No.1, pp. 226–232, Mar. (2008).
[5] Heier.S, Grid Integration of Wind Energy Conversions. Hoboken, NJ: Wiley, 2007, pp. 256–259.
[6] Hook K.S, Liu.Y, and Atcitty.S, “Mitigation of the wind generation integration related power quality issues by energy storage,” EPQU J., Vol. XII, No. 2, 2006.
[7] Kinjo.T and Senjyu.T, “Output leveling of renewable energy by electric double layer capacitor applied for energy storage system,” IEEE Trans. Energy Conv., Vol. 21, No. 1, Mar. (2006).
[8] Manel.J, “Power electronic system for grid integration of renewable energy source: A survey,” IEEE Trans. Ind. Electron., Vol. 53, No. 4, pp. 1002–1014, (2006), Carrasco.
[9] M. I. Milands, E. R. Cadavai, and F. B. Gonzalez, “Comparison of control strategies for shunt active power filters in three phase four wire system,” IEEE Trans. Power Electron., vol. 22, no. 1, pp. 229– 236, Jan. (2007).
[10] Mohod.W and Aware M.V, “Grid power quality with variable speed wind energy conversion,” in Proc. IEEE Int. Conf. Power Electronic Drives and Energy System (PEDES), Delhi, Dec. (2006).
[11] Mohod.W and Mohan Aware.V “A STATCOM-Control Scheme for Grid Connected Wind Energy System for Power Quality Improvement,” IEEE SYSTEMS JOURNAL, VOL. 4, NO. 3, SEPTEMBER (2012).
[12] Pai.S and Hung S.I, “Design and operation of power converter for micro turbine powered distributed generator with capacity expansion capability,” IEEE Trans. Energy Conv., Vol. 3, No. 1, pp. 110–116, Mar. (2008).
[13] Senjyu.T and Kinjo.T, “Output leveling of renewable energy by electric double layer capacitor applied for energy storage system,” IEEE Trans. Energy Conv., Vol. 21, No. 1, Mar. (2006).
[14] Sheng Li; Qi Zhao; Cheng Chen; Yan Xu, “A comparision study on voltage stability bifurcation control ability of SVC and STATCOM,”IEEE Trans .Energy Conv.,Vol.2,No.1,Mar.(2012).
[15] Tsili.M and Papathanassiou.S, “A review of grid code technology requirements for wind turbine,” Proc. IET Renew.power gen., Vol. 3, pp. 308–332, (2009).
[16] Yao.D.L, Choi S.S , Tseng K.J , and Lie T.T, “A statistical approach to the design of a dispatchable wind power—Battery energy storage system,” IEEE Trans. Energy Conv., Vol. 24, No. 4, Dec. (2009).
[17] Zeng.J and Z. Yan, “A novel hysteresis current control for active power filter with constant frequency,” Elect. Power Syst. Res., Vol. 68, pp. 75–82, (2004).
[18] Zeineldin,H.H and Alobaidli,K.A, ,“A hybrid STATCOM for economical system installation with proven dynamic and transient response”, IEEE Trans.Energy Conv.,Vol.3.No.4,march (2013).

Full Paper: Click Here